Flipping a single section with a completed tracing
See Serial section reconstruction overview
You have completed tracing a data file and notice that one of the sections appears to be upside down.
Flip the problematic section:
- Select the section to flip. How?
- In the Serial Section Manager, click the icons Show current section and Gray other sections.
- Select the section to flip; the selected section appears in color, while all other sections appear with gray lines.
- Optional : If Z positioning is critical, determine the z position of your deepest traced point or the bottom of the tissue section for the section to be flipped with Ortho View.
- Flip vertically (or horizontally). How?
- Click Trace>Edit>Select All Objects.
- Right-click in the Tracing window and select Flip Selected Objects from the menu.
- In the Flip Selected window, select Horizontal and/or Vertical flip.
- Optional : If Z positioning is critical, correct the depth values of the flipped data to match them up with the original sections. How?
- Select Trace>Tools drop-down menu>Correct z shrinkage. Enter "-1" as the factor .
- Calculate the correct delta.
- Right-click and select Modify Z Position. Select Shift Z values and enter the delta value calculated in step 4.b.
- Align the section with those above and below it. How?
- Click Trace>Edit>Select All Objects.
- Right-click and select Move Selected Objects or Rotate Selected Objects.
Use to see the entire tracing while you reposition the section.
Example
- Select Section 2 to flip.
- Deepest traced point: Z=600.00 (see illustration above).
- Flip vertically.
- Correct the depth values of the flipped data to match them up with the original sections.
- Shrinkage correction: -1. The deepest Z value is now -600.00 and all other points have a negative z value.
- Correct delta: The deepest traced point located at -600.00 should actually be located at 500.00 (the top of the section). This means that we need to shift the Z values in this section by 1100:
1100=500.00-(-600.00)
- Right-click and select Modify Z Position. Select Shift Z values and enter 1100.
- Verify that the deepest traced point Z value is now 500.00.
- Align the section with those above and below it.
See Correcting for an upside down section while tracing if you encounter an upside-down section while tracing neurons or contours.