One section per image with contours already traced
Serial section reconstruction procedure
If contours need to be traced, consult this procedure instead.
Scaling should be identical for all the images.
- Organize sections:
Use File>Open>Data files into serial sections to open the desired sections.
- Register and align sections:
- In the Serial Section Manager, select Show current section and Display flanking sections.
Display flanking sections lets you view the tracings of the previous and subsequent sections.
- Highlight the 2nd section in the Serial Section Manager.
- Select Move>Navigate>Move images and tracing and drag to align with the first section.
- Refine the alignment using the Select Object or Match points method.
- Highlight the next section in the Serial Section Manager.
- Repeat Steps c-e until all sections are aligned.